ProScale™
General Instruction Manual
Includes: ProScale Model 150 & 250
ProStop
Measurement Table Kits
ProPanel
ProCaliper
Digital Displays
Accurate Technology, Inc.
270 Rutledge Rd. Unit E
Fletcher, NC 28732 USA
800 233-0580 828-654-7920
Fax 828-654-8824
www.proscale.com
info@accurate-technology.com
Seitenansicht 0
1 2 3 4 5 6 ... 58 59

Inhaltsverzeichnis

Seite 1 - ProScale™

ProScale™ General Instruction Manual Includes: ProScale Model 150 & 250 ProStop Measurement Table Kits ProPanel ProCaliper Digital Displ

Seite 2 - SAFETY WARNING

10System Descriptions ProScale Model 150 systems use ABS style scales, ABS style readheads, and ABS style displays. Neither the scale nor readhea

Seite 3 - Table of Contents

11 Other Accurate Technology System Descriptions (See individual product manuals for detailed descriptions & operation for the products below)

Seite 4

12Specifications Accuracy: ± .165mm per meter to ± .2mm max. error ± .002in per foot to ± .008in max. error Repeatability: 0.01mm or .001in.

Seite 5 - Introduction

13 ProPanel: Two years from date of purchase ProCaliper: Two years from date of purchase Operating Temperature: 0 to 51°C/ 32 to 120°F

Seite 6 - ProScale Technology

14Connector Link SECTION 2 PRODUCTS ProScale Model 150 ProScale Model 150 systems are general purpose absolute measuring syste

Seite 7 - . In fact

15The Display should be mounted in a location which allows for easy viewing by the machine operator. The location of the parts should also safeguard

Seite 8 - Style Pattern

16Calibration: Once installed, ProScale can be calibrated easily and quickly. Following is an example for calibrating ProScale on an industrial sand

Seite 9 - Readheads

17 ProScale Model 250 ProScale Model 250 systems are general purpose absolute measuring systems designed for taking measurements up 6.0m (23

Seite 10 - System Descriptions

183. Mount the scale using M4 (or #6) screws. It may be necessary to use washers or spacers to ensure a good mount if the scale is to be mounted on

Seite 11

195. Reinstall the readhead if it has been removed from the scale. Care should be taken to not damage the readhead’s sensitive internal ground fing

Seite 12 - Specifications

2Warranty Accurate Technology, Inc., warrants this product against defective parts and workmanship commencing from the date of original purchase. Up

Seite 13

203. Measure the length of the part with the most precise measuring tool available (i.e. digital calipers). 4. Press the zero key on the ProScale d

Seite 14 - ECTION 2 PRODUCTS

21 ProStop ProStop is a complete digital stop and fence system for chop saws, radial arm saws, and miter saws. ProStop is easy to install

Seite 15 - READHEAD

22or right infeed), it may be necessary to change the position of JP3 inside the digital display to reverse the reading direction. (See section 3 re

Seite 16

235. Press and hold the PLUS key to scroll until the measurement is displayed (the longer the PLUS key is held down, the faster the display will scr

Seite 17 - ProScale Model 250

24 ProKits ProKits are easy to install. By following the basics of good installation, reliable, error-free operation is assured. Because in

Seite 18

25 Measurement Table Kit Measuring Table Kits are easy to install. By following the basics of good installation in this section, reliabl

Seite 19

268. Plug the readhead into the display. Move the assembly from left to right and note if the display's readings increase or decrease. Depend

Seite 20

27 ProPanel ProPanel is a portable measuring system capable of edge-to-edge, edge-to-hole, hole-to-hole, and corner-to-corner measurements up

Seite 21 - ProStop

28 Hole-To-Hole Measuring: Install the two full cone attachments. Close the ProPanel. Use the plus or minus keys to adjust the display to exactly 3

Seite 22

29 ProCaliper ProCaliper is easy to install and use. By following the installation instructions in this section, reliable, error-free operat

Seite 23

3Table of Contents SECTION 1 GENERAL INFORMATION... 5 Introduction...

Seite 24 - ProKits

30mounted without any bending stress to the rail, which will cause measuring inaccuracies. 3. Check that the bolts extending through the rail will n

Seite 25 - Measurement Table Kit

31To Make Relative Measurements: Measure the first part. Change to Incremental mode by pressing the red button on the display. Press the zero key.

Seite 26

32SECTION 3 DISPLAY OPERATION Digital Display Descriptions Accurate Technology makes several digital displays for use with its products. Al

Seite 27 - ProPanel

33 Basic and Incremental Displays Changing the Measurement Readout: Press the MODE key to change the measurement readout. The current measurement

Seite 28

34Incrementing/Decrementing the Display The PLUS or MINUS keys on the digital display are used to adjust a reading. For instance, if the display ne

Seite 29 - ProCaliper

35 Note: Locking the keypad may cause the PLUS and MINUS keys to function differently. (See “Pattern Adjustment”.) The zero key will not function

Seite 30

36Standard and SPC Displays Changing the Measurement Readout: Press the MODE key (while in ABS mode) to change the measurement readout. The curren

Seite 31

37Setting INC Position Momentarily press the ABS/INC button. This switches the display to incremental mode. Press the ZERO key. Any measurement n

Seite 32 - Digital Display Descriptions

38Locking the Keypad The display allows the keypad to be locked so the current settings can't be accidentally changed by depressing the ZERO, P

Seite 33

39 SPC (Statistical Process Control) The data format and connector style of the ProScale SPC output is the same as Mitutoyo SPC. This is an industr

Seite 34 - Basic displays)

4SECTION 4 MISCELLANEOUS ...47 Installation Notes ...

Seite 35

401/4 DIN Panel Mount Displays Power Supply There are two versions of the 1/4 DIN Panel mounted displays. The first version requires power supplie

Seite 36 - Standard and SPC Displays

41Changing the Measurement Readout: Press the MODE key to change the measurement readout. The current measurement readout is saved when power is of

Seite 37

42 Auto Save When power is turned off, ProScale remembers the current measurement and current mode of operation. When ProScale is turned back on, t

Seite 38

43Programmable (Including Externally Powered Displays) Display Programming This display must be programmed for the user's preferences before u

Seite 39

44and show the next parameter value (right side). After the ninth parameter, pressing the MODE key will restart the parameter list at 1. To exit the

Seite 40 - 1/4 DIN Panel Mount Displays

45one second). To return to the ABS coordinate system, press the MODE key twice within 2 seconds. Note: If disabled, INC mode cannot be activated u

Seite 41

46Summary of Digital Display Keypad Functions On/Off: Turns display on or off with each depression. MODE: Function varies depending on operating st

Seite 42

476.3mm (.25") 1.9mm (.07) SECTION 4 MISCELLANEOUS Installation Notes Scales Scales used for individual products should never be mix

Seite 43

48Displays The tables below show display options that may be configured by the installer. When shipped, displays are set to allow the maximum numbe

Seite 44

49Incremental Display Part #701-1495-002 Basic Display Part #701-1495-001 Standard Display Part # 701-1500-001 Jumper Position Functi

Seite 45

5SECTION 1 GENERAL INFORMATION Introduction ProScale™ digital measuring systems are high-precision electronic devices for making linear meas

Seite 46 - Mounting the Display

50SPC Display Part # 701-1505-002 Jumper Position Function Notes JP1 A Increased resolution (Decimal inch mode only) Display format: X

Seite 47 - Installation Notes

51To enable the programming options, JP1 inside the display must be set to the B position. Programmable Battery Display # 701-1115-001 Programmabl

Seite 48

5210mm13mm91mmPanel Mount Display Part # 701-1525-001 SPC ConnectorReadHead Connector Power Connector Display Options

Seite 49 - Factory Settings

5310mm13mm91mmPanel Mount Display Part # 701-1550-002 ¼ DIN Panel Mount Display (105 mm square) SIZE: Cutout dimen

Seite 50 - Do not change

54ProPower DC Power Supply Part # 901-0200-001 Specifications Input Power • 110-120 VAC 60Hz. • 220-240 VAC 50Hz. • 24 VAC 50/60Hz. •

Seite 51 - (if equipped)

55Frequently Asked Questions Why is there an “Err 2” message on the display? If the read head is off the scale, or the readhead cable is unplugged f

Seite 52 - 24 VAC or 24 VDC @

56Product Communication: ProScale's electrical interface allows the readhead position to be read by a computer or other instrument. Interface

Seite 53

57Abbe Error Abbe error is a condition which may not be visible to the human eye, but will affect linear measurements. Be sure to take precautions w

Seite 54 - Manual

A Abbe error, 26 ABS Position, 38 absolute, 7 absolute systems, 7 Accuracy, 12 Auto Save, 36 B Batteries, 37 BATTERY CLIPS, 48 Battery Life:, 12 Beari

Seite 55 - Frequently Asked Questions

2PLUS, 48 ProCaliper, 10, 30 ProCase, 11 Programming, 45 ProKits, 11, 24 ProLine, 11 ProPanel, 10, 28 ProPower, 11 ProScale Model 150, 14 ProScale Mo

Seite 56

6ProScale Technology All ProScale systems consist of a SCALE, READHEAD, and a DISPLAY. The SCALE consists of a series of conductive patterns on a

Seite 57 - Abbe Error

7Scales-Incremental Vs. Absolute Simply stated, an Incremental system measures the distance it has traveled relative to a starting point. An abso

Seite 58

8All ABS style scales have a “zigzag” pattern etched onto the green laminate. Take care to not damage this etching or remove the green coating. The

Seite 59

9Readheads ABS style readheads have “BLACK END OF SCALE” labels on the cover, and the telephone-style wire exits from the corner of the housing.

Kommentare zu diesen Handbüchern