Accurate Technology ProScale Installationshandbuch Seite 14

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 48
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 13
Operation Manual for LCD Digital Readouts Page 14 of 48
SECTION 3 OPERATION
Fundamental Operation
The following operations & functions apply to the Basic, General Purpose and
Panel mount LCD Digital Readouts.
KEY TIMING
The keys pictured below have multiple functions. Timing (how long a key is
depressed) is important. This manual uses the term momentarilyto describe
a key press and release of less than .8 seconds. Whereas “press and holdis
used to describe a key press and release of 1 second or longer.
See Table Below:
A function is executed on the “key release” for momentary key presses.
A function is executed after the allotted time has elapsed for “press & hold”
operations. See Table Below:
Momentarily Press Press & Hold
UNITS
Cycles measurement units:
inches, fractions, mm
No effect
(in programming mode) Increments program parameter list Displays Pr #
Plus (+) increments displayed value increments faster
(in programming mode) increments parameter value increments faster
Datum
forces reading to programmed
datum value
After 6 seconds: battery voltage
After 9 seconds: Temperature
(in programming mode) forces parameter to factory default no effect
Minus (-) decrements displayed value decrements faster
(in programming mode) decrements parameter value decrements faster
Momentarily Press & Hold
How long a key is pressed? Less than .8 seconds More than 1 second
When is key function executed? On key release While holding